Projects
Case studies
The difficult jobs, the challenges behind them, and how we solved them.
AfterBefore
Corrosion Control CoatingsGreen Diamond
Corrosion control and protective coating of a 160-foot ship-loading tower in a severe coastal environment.
- The challenge
- Near-constant rain, marine exposure, difficult access, and active vessel operations complicated every phase of the work.
- The result
- Completed on time and on budget with zero safety incidents, extending protection of the tower and supporting steel.
AfterBefore
Coating repairNOAA, San Diego
Urgent corrosion repair and recoating of a critical exhaust fan at NOAA’s Southwest Fisheries Science Center.
- The challenge
- Severe marine corrosion, sensitive surrounding equipment, tight fan tolerances, and an opening deadline days away.
- The result
- Extensive corrosion was repaired and protected with a 3-coat DTM system, with the expanded work completed ahead of schedule.
Exterior recoatCapitol Records
Exterior restoration and recoating of approximately 51,000 square feet on the iconic 13-story Capitol Records Building.
- The challenge
- Circular architecture, difficult access, varied surface deterioration and persistent rain complicated repairs and coating application.
- The result
- The building’s exterior was repaired, recoated and protected, restoring a clean, consistent appearance to the landmark tower.
Chemical resistant coatingsMortuary Deck
Replacement and recoating of a second-floor mortuary floor while the facility remained in operation.
- The challenge
- Concealed deck conditions, contamination control, waterproofing, and a finish resistant to formaldehyde.
- The result
- A new sloped, sealed epoxy floor was completed on schedule and within budget without interrupting business operations.
Epoxy coatingsSutro Tower
Corrosion remediation and protective coating of the interior structural steel at San Francisco’s 1,000-foot Sutro Tower.
- The challenge
- Extreme vertical access, confined work areas, and constant coastal fog made logistics, preparation, and coating especially difficult.
- The result
- The first two legs were completed on time and within budget, extending protection of the structural steel and earning additional project phases.
More case studies
Other Challenges. Proven Solutions.
More jobs backed by our experience.
- Garage deck coating
Wilshire Rodeo Parking
Wilshire Rodeo Plaza needed restoration of the coated concrete floor in its underground parking and valet area in Beverly Hills. Raider Painting removed the existing coating and prepared the concrete for a new high-traffic epoxy flooring system. The work included mechanical surface preparation, coating of the driving and parking areas, and new pavement markings. Entrance and exit ramps also received added aggregate for a non-skid surface.
- The challenge
- The existing floor coating first had to be mechanically removed before the concrete could be properly prepared. The surface was shot-blasted to clean and profile the concrete, while high areas were corrected with diamond grinding. The new flooring needed to withstand the demands of a high-traffic parking and valet area while providing a finished appearance appropriate for the Beverly Hills retail and office property. Careful preparation was essential to the performance and appearance of the completed system.
- The result
- Raider installed a dense, high-traffic epoxy flooring system designed for long-term service, with sand aggregate added at the entrance and exit ramps for improved traction. Parking stalls, accessible spaces, and traffic markings were repainted to complete the restoration. The project was completed on time and within budget. The client praised Raider’s project management and the finished valet area, noting that the completed space was well suited for its high-end retail and office visitors.
- Deck coating
Helipad
Raider Painting restored a worn aluminum helipad deck with a specialized waterproofing and anti-skid coating system. The project included complete surface preparation, seam sealing, patching, coating, and detailed landing markings. Multiple coating layers and aggregate provided the durable, slip-resistant surface required for the deck. Final markings and identifiers were completed in accordance with FAA-approved requirements.
- The challenge
- The aluminum deck required a different preparation approach than a conventional concrete or steel surface. Magnetic shot-blasting equipment was used to remove the existing coating, followed by thorough removal of remaining blast media from between the aluminum panels. Panel seams also required individual attention, along with extensive patching and sanding to create a level surface. Proper preparation was critical before the new waterproofing and anti-skid system could be installed.
- The result
- The completed deck received a 100% solids epoxy coating system with aggregate broadcast to refusal, followed by a polyurethane finish coat in the specified color. Every panel seam was sealed with elastomeric polyurethane caulking to complete the waterproofing work. An artist laid out the helipad circles, while Raider’s crew completed the markings, insignias, landing identifiers, and stenciled numbers. The finished helipad combined a renewed, durable deck surface with the required FAA-approved markings.
- High temperature coatings
Weber Metals
Weber Metals is home to a massive 12,000-ton press requiring specialized coatings for an extreme industrial environment. Raider Painting provided coating work on the press as well as its large grease pit. The selected coating system needed to withstand temperatures reaching 1,000°F. The project combined demanding surface conditions with very limited application windows.
- The challenge
- Extreme operating temperatures and short application windows made coating selection, preparation, and execution especially important. The grease pit presented an additional challenge because contaminants had to be thoroughly removed before coating could begin. The surface then required careful preparation to provide proper adhesion for the new system. With conditions this demanding, conventional coatings and preparation methods were not sufficient.
- The result
- After cleaning and preparing the surfaces, Raider applied a specialized epoxy coating system capable of withstanding temperatures up to 1,000°F. The grease pit received the same attention to cleaning and surface preparation before application of the protective coating. The completed work provided a coating system suited to the unusually demanding conditions surrounding the press. Raider successfully completed specialized coating work on one of the most distinctive pieces of industrial equipment in the facility.
- Steel Structural Coatings
UPRR Colton Yard
Raider Painting completed a broad range of commercial and industrial coating work under a two-year contract at Union Pacific Railroad’s Colton facility. The scope included structural steel protection, specialized deck systems, and high-performance anti-skid coatings in critical work areas. Hundreds of individual coating applications required thousands of gallons of specialized materials across the large facility. The work combined demanding coating requirements with the operational challenges of an active railroad yard.
- The challenge
- Working around active railroad operations required strict safety protocols, careful planning, and constant schedule flexibility. Work stopped when trains were moving through designated areas, while crossing active tracks could delay crews and equipment for hours. Structural steel coating also faced aggressive deadlines, requiring near-round-the-clock application shifts to maintain the schedule. At the same time, surface preparation and coating work had to meet the requirements of each individual application.
- The result
- Over the course of the contract, Raider completed extensive structural steel, deck, and anti-skid coating applications throughout the facility. Rapid-cure deck systems helped minimize downtime in high-traffic areas, while mechanical surface preparation provided the proper profile for long-term coating adhesion. Anti-skid systems improved critical work areas where slip hazards were a concern. The project delivered long-lasting protection across a large, active industrial facility while working within demanding operational and access constraints.
Projects